<%@LANGUAGE="VBSCRIPT" CODEPAGE="936"%> <% option explicit response.buffer=true %> <% Dim rs,Title,Content ChannelID = 1 Title = ReplaceBadChar(Trim(Request("Title"))) if Title = "" then Title = "Company Profile" 'set rs = conn.execute("select Content from DE_Article where ChannelID=" & ChannelID & " and Title='" & Title & "'") set rs = conn.execute("select Content from DE_Article where ChannelID=" & ChannelID & " and Title='profile'") if rs.eof and rs.bof then Content = "
  • No Found!
  • " else Content = Replace(rs(0),"[UploadDir]",UploadDir) end if set rs = nothing %> Quanzhou Haohan Energy Saving Construction Material Corp.,Ltd.
      Solar Water Heater    Solar Fencing Light    Solar Garden Light    Solar Generator    Solar Street Light

    Catalog of Solar Water Heater

    High Pressure Vacuum Tube
    Introduction:
    Thermosyphon solar water heater relies on the natural circulation of water between the collector and the tank. As water in the vacuum tubes is heated it rises naturally into the tank, while cooler water in the tank flows down to the bottom of the vacuum tubes, causing circulation throughout the system. the cold water gained heat indirectly contacts with the water in the tank but through a copper tube in the tank.


    Technical Specification


    Tank material
    stainless steel 304 2B
    Manifold Casing Material
    stainless steel
    Frame Material
    stainless steel
    Pipe in the tank  
    1.2mm*12.5mm Copper
    Insulation
    Polyurethane 50mm
    Rubber Seals and Rings
    UV stabilized high temperature silicone rubber
    standard Pressure
    ¡Ü1.2Mpa
    Mounting angle
    15¡æ-50¡æ
    Collector mounting
    Flat roof/inclined roof
    MODEL
    Absorb area(m2)
    Heat pipe
    Capability of the tank
     
    Package measurement of the tank(cm)
    diameter
    length
    No.
    HS-PV1800/58-16
    1.50
    ¦µ58mm
    1800mm
    16
    100/140
    46*46*155
    HS-PV1800/58-20
    1.88
    ¦µ58mm
    1800mm
    20
    130/180
    46*46*180
    HS-PV1800/58-24
    2.26
    ¦µ58mm
    1800mm
    24
    150/200
    46*46*214
    HS-PV1800/58-28
    2.63
    ¦µ58mm
    1800mm
    28
    180/250
    46*46*245
    HS-PV1800/58-32
    3.00
    ¦µ58mm
    1800mm
    32
    200/280
    46*46*270

    Vacuum Tube
    Introduction:
    This is the simplest and typically the least expensive active system to install. There is no heat exchanger, which allows efficient heat transfer directly to the water. The system Operates at standard line pressure. It is simple to add capacity to the system if demand changes. The system integrates easily with existing systems. When there is not enough energy for sun, an electrical back up element will be automatically switched on by controller.


    Technical Specification


    Tank material
    stainless steel 304 2B
    Manifold Casing Material
    stainless steel
     
    Frame Material
    stainless steel
    Insulation
    Polyurethane 50mm
    Rubber Seals and Rings
    UV stabilized high temperature silicone rubber
    standard Pressure
    ¡Ü0.15Mpa
    Mounting angle
    15¡æ-50¡æ
    Collector mounting
    Flat roof/inclined roof
    MODEL
    Absorb area(m2)
    Heat pipe
    Capability of the tank  N/G
     
    Package measurement of the tank(cm)
    diameter
    length
    No.
    HS-V1500/47-20
    1.27
    ¦µ47mm
    1500mm
    20
    110//140
    46*46*160
    HS-V1500/47-24
    1.52
    ¦µ47mm
    1500mm
    24
    130/180
    46*46*190
    HS-V1500/47-28
    1.78
    ¦µ47mm
    1500mm
    28
    150/220
    46*46*218
    HS-V1500/47-32
    2.03
    ¦µ47mm
    1500mm
    32
    180/230
    46*46*245
    HS-V1500/47-36
    2.28
    ¦µ47mm
    1500mm
    36
    200/260
    46*46*270
     
     
     
     
     
     
     
    HS-V1800/58-16
    1.50
    ¦µ58mm
    1800mm
    16
    100/140
    46*46*155
    HS-V1800/58-20
    1.88
    ¦µ58mm
    1800mm
    20
    130/180
    46*46*180
    HS-V1800/58-24
    2.26
    ¦µ58mm
    1800mm
    24
    150/200
    46*46*214
    HS-V1800/58-28
    2.63
    ¦µ58mm
    1800mm
    28
    180/250
    46*46*245
    HS-V1800/58-32
    3.00
    ¦µ58mm
    1800mm
    30
    200/280
    46*46*270
     
     
     
     
     
     
     
    HS-V2000/70-16
    2.02
    ¦µ70mm
    2000mm
    16
    130/180
    51*51*175
    HS- V2000/70-20
    2.52
    ¦µ70mm
    2000mm
    20
    160/230
    51*51*215
    HS- V2000/70-24
    3.02
    ¦µ70mm
    2000mm
    24
    190/280
    51*51*249
    HS- V2000/70-28
    3.52
    ¦µ70mm
    2000mm
    28
    220/320
    51*51*285
    HS- V2000/70-30
    3.78
    ¦µ70mm
    2000mm
    30
    240/345
    51*51*305

    Price of the tube (FOB Xiamen):

    1500/47:
    1800/58:
    2000/70:

    £¨available, please contact us for details£©

    Package measurement of the tubes£º

    1500/47: a) 300*270*1550mm 20pcs b) 330*270*1550mm 24pcs
    1800/58: 280*250*1880mm 12pcs
    2000/70: 350*200*2070mm 8pcs

    Package measurement of the frame£º

    For HS-V2000/70: 2600*320*130mm
    For HS-V1800/58: 2500*320*130mm
    For HS-V1500/47: 2000*460*130mm

    Flat Plate Separated

    Introduction:

    The flat plate system contains solar flat plate collector, storage water tank,
    pump station with controller, piping, connections, valves
    etc parts. And the flat plate collector can be installed on the roof, wall, garden
    to face most of sun light. The storage water tank can be put anywhere as you
    like. The pump on/off is controlled through temperature difference by regulation.
    This system can be combined with gas boiler, oil boiler or electric heater.


    Technical Specification


    1.Flow tube: Copper and Aluminum unified core or all copper core: Header pipe diameter up to 22mm or 25mm, high intension, and strong pressure resistance.
    2.Absorber plate: The surface of copper and aluminum unified plate is selective absorbance coating, long service life over 15 years, and enduring high temperature.
    3.Glazing: Tempered Glass, high transmittance, good heat preservation, firm and long service life.
    4.Working pressure: 0¡Ü1.2MPa
    5.Enclosure: Aluminum Alloy Profile, beautiful appearance and anti-corrosion.

    MODEL
    Working pressure
    Measurement of the plate
    Glazing type
    Head copper pipe
    Branch copper pipe
    Absorber material
    Absorb area(m2)
    Capability of the tank
    HS-FA
    0.1
    200*100*7.6cm
    General glass
    25*0.31mm
    10*0.31mm
    Aluminum
    2
    200L
    HS-PFA
    0.6
    200*100*7.6cm
    Tempered Glass 4mm
    25*0.7mm
    10*0.7mm
    Aluminum
    2
    200L
    HS-PFC
    0.6
    200*100*7.6cm
    Tempered Glass 4mm
    25*0.7mm
    10*0.7mm
    Copper 0.15mm
    2
    200L